NCS-TT106 Temperature Transmitter
NCS-TT106 uses digital technology, so it can connect with many types of thermocouple and thermo resistive sensors. It has wide range and simple interface between field and control room, which reduces the expense of installation, operation and maintenance.
NCS-TT106 Smart Temperature Transmitter:
1. Support 4 types of thermal resistance and 8 types of thermocouple
2. Thermal resistance supports 2-wire, 3-wire and 4-wire
3. The cold junction compensation accuracy of voltage signal can reach ± 0.15 ℃
4. High precision (better than grade 0.1), low temperature drift (better than ± 50ppm/℃)
Product Description
NCS-TT106 Temperature Transmitter: is an indispensable field device in process control. NCS-TT106 integrates abundant function blocks and realizes not only general measurement function but also complicated control strategy.
NCS-TT106 Temperature Transmitter Size Shown:
Size(Unit:mm)
NCS-TT106 Temperature Transmitter Wiring Shown:
NCS-TT106 uses digital technology, so it can connect with many types of thermocouple and thermo resistive sensors. It has wide range and simple interface between field and control room, which reduces the expense of installation, operation and maintenance.
NCS-TT106 supports HART, FF, and PA protocols. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.
NCS-TT106 Temperature Transmitter technical indicators of thermal power resistance:
RTD Accuracy (25℃)
Signal type | Suggested range | Accuracy(25℃) | Temperature drift(per ℃) |
Resistance Signal | 0~500Ω | ±0.04Ω | ±0.001Ω |
0~4000Ω | ±0.35Ω | ±0.015Ω | |
PT100 | -200 ~ 850℃ | ±0.15℃ | ±0.003℃ |
PT1000 | -200 ~ 850℃ | ±0.15℃ | ±0.005℃ |
CU50 | -50 ~ 150℃ | ±0.15℃ | ±0.005℃ |
CU100 | -50~ 150℃ | ±0.10℃ | ±0.003℃ |
NCS-TT106 Temperature Transmitter thermo couple technical indicators
Thermal Couple Accuracy (25℃)
Signal type | Suggested range | Accuracy(25℃) | Temperature drift(per ℃) |
mV | -100mV ~ +100mV | ±0.025mV | ±0.001 mV |
B | 500 ℃~ 1810℃ | ±0.77℃ | ±0.050℃ |
E | -200 ℃~ 1000℃ | ±0.20℃ | ±0.025℃ |
J | -190 ℃~ 1200℃ | ±0.35℃ | ±0.01℃ |
K | -200℃ ~ 1372℃ | ±0.40℃ | ±0.025℃ |
N | -190℃ ~ 1300℃ | ±0.50℃ | ±0.015℃ |
R | 0℃ ~ 1768℃ | ±0.75℃ | ±0.023℃ |
S | 0 ℃~ 1768℃ | ±0.70℃ | ±0.023℃ |
T | -200℃ ~ 400℃ | ±0.35℃ | ±0.015℃ |
NCS-TT106 Temperature Transmitter Basic Parameter:
Input Signal | Pt100、Pt1000、CU50、CU100、0~500Ω、0~4000Ω B,E,J,N,K,R,S,T eight kinds of Thermocouple -100mV~100mV voltage signal |
Channel | Single |
RTD Wiring | 2-wire, 3-wire, 4-wire |
Bus Power | HART:(11-35)VDC/(12-30)VDC FF/PA:(9-32)VDC/(9-17.5)VDC |
Bus Signal | HART,FF,PA current mode |
Electric isolation | 1000VAC |
Working Temperature | -40℃~85℃ |
Humidity Range | 5%~95%RH |
Start Time | ≤5s |
Refresh Time | 0.5s |
EMC | GB/T 18268.1-2010 |
Protection | Terminal IP00, housing IP40 |
Voltage effect | ±0.005%/V |
Alarm signal | Alarm output can be set as 3.5…23 mA Upper/lower limit current 20.8mA / 3.8mA |
Current accuracy | 0.03% |