Many products for you to choose from
NCS-PT105IIM Smart Pressure Transmitter
NCS-PT105IIM series Smart Pressure Transmitter supports HART, FF, PA and DP protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc..
NCS-PT105IIM Smart Pressure Transmitter:
1. Support the latest versions of FF H1, PROFIBUS PA and HART protocols
2. Pass FF interoperability, intrinsically safe explosion-proof, flameproof certification
3. Pressure types include gauge pressure, absolute pressure, micro differential pressure, differential pressure and high static pressure
4. High precision: ± 0.075% of full range (20 ℃, range ratio within 10:1)
5. Long term stability: ± 0.2% of the maximum range within 5 years
Product Description
NCS-PT105IIM series Smart Pressure Transmitter: with advanced mature, reliable sensors has been designed meticulously by combining advanced microprocessor technology and digital capacitance measurement technology. The powerful functions and high-speed computing capability of the microprocessor make it have excellent qualifications such as smart, high precision, high reliability, stable zero and so on. Its LCD can display many physical parameters (e.g. pressure, temperature, current and so on). It can realize the functions such as zero adjustment, range settings by key-press operation, and it is easy for field testing.
NCS-PT105IIM Smart Pressure Transmitter Size Shown:
Size(Unit:mm)
NCS-PT105IIM Smart Pressure Transmitter Wiring Shown:
NCS-PT105IIM series Smart Pressure Transmitter supports HART, FF, and PA protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc..
As a transitional communication protocol in fuildbus, HART protocol achieves digital transmission on the existing analog transmission lines, and is compatible with existing analog signal control system. Either FF H1 or PROFIBUS PA is a new generation of digital communication protocol, used in field connection, and linking field devices. International Standard IEC61158-2 is used in physical layer. Therefore, either FF H1, PROFIBUS DP or PROFIBUS PA is fieldbus actually.
NCS-PT105IIM Smart Pressure Transmitter type of measurable pressure:
Model | Pressure type |
NCS-PT105IIM SG | Gauge pressure transmitter |
NCS-PT105IIM SA | Absolute pressure transmitter |
NCS-PT105IIM SD | Differential pressure transmitter |
NCS-PT105IIM Smart Pressure Transmitter Basic Parameter:
Measure object | liquid, gas,stream |
Power | 9~32V DC (FF,PA) 9~32V DC (FF, PA Explosion-proof instrument) 11.9~42 V DC (HART) 11.9~30 V DC (HART Explosion-proof instrument) 10~30V DC (DP) |
Output | Analog:2 wire 4~20mA Digital:HART, FF ,PA and DP signal |
Load resistant | 0~1500ohm(common) 230~1100ohm(with HART) |
Insulation | Input and output insulating voltage:500Vrms(707VDC) |
Display | Optional 6 bits digital number or 5 bits characters LCD display |
Temperature scale | Work temperature:-40 ~ 85℃ (No display) -30 ~ 70℃ (display) -30 ~ 60℃ (Explosion-proof Ex ia IIC T4 Ga) -40 ~ 60℃ (Explosion-proof Ex d IIC T4/T6 Gb) |
Allowed media temperature measured | -40 ℃ ~ 110 ℃(Type name include ‘IC’) -40 ℃ ~ 149 ℃ (silicone oil) -40 ℃ ~ 204 ℃ (sylthlem800) -18 ℃ ~ 204 ℃ (inert liquid) -40 ℃ ~ 104 ℃ (others) |
Humidity scale | 5%~100%RH |
Start time | ≤ 8 seconds (HART) ≤ 12 seconds (PA, DP) ≤13 seconds (FF) |
Quiescent current (FF,PA) | ≤14mA |
Refresh time | 0.2 seconds |
Dump adjusting | Time constant 0~32 seconds |
Change of cavity | < 0.16 cm3 |
Protection grade | IP65/IP67 |
Explosion-proof | DA: Ex d IIC T6 Gb DC: Ex d IIC T4 Gb IC: Ex ia IIC T4 Ga |
Protection grade | No explosion-proof type: enclosure protection grade reaches IP65 Flameproof type: enclosure protection grade reaches IP67; Intrinsically safe type: enclosure protection grade reaches IP65. |
Electromagnetic compatibility | Conform to immunity requirements for industrial sites in GB/T 18268.1 Conform to the requirements of GB 9254 for the disturbance degree of Class A equipment |
NCS-PT105IIM Smart Pressure TransmitterPerformance Index:
Precision | ± 0.2%, ± 0.1% upper range limit |
Temperature effect | Total effects per 10℃ change: ±(0.1+0.015TD)% of maximum range (TD means range ratio) |
Long time stability | In 5 years, ±0.2% of maximum range |
Location installed effect | Installed at any position, up to 400 Pa can be corrected by the reset function |
<< Previous page