G1003 HART to Modbus Converter
G1003 HART to Modbus converter realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the converter, HART terminal is master station, Modbus terminal is slave station.
G1003 HART to Modbus Converter:
1.HART protocol to Modbus-RTU/ASC II protocol
2.Hardware interface RS232/422/485
3.Configured as HART first master device or second master device
4.Can work in a point-to-point or multipoint mode
5.Connect up to 15 HART slave devices in multipoint working mode
6.Supported HART command can be configured
7.Support HART burst mode
Product Description
G1003 HART to Modbus converter realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the converter, HART terminal is master station, Modbus terminal is slave station.
Outline dimension drawing of G1003 HART to Modbus converter:
Unit: mm
Structure diagram of G1003 HART to Modbus converter :
1 | Teminal | 2 | Bottom Housing | 3 | Main Board | 4 | Upside Housing |
Data Access Diagram of G1003 HART to Modbus converter :
Detailed data list of G1003 HART to Modbus converter:
Basic parameters:
Name | Description |
Gateway Power | 9~30VDC |
Modbus Interface | RS-232/RS-422/RS485 |
HART Interface | HART digital signal |
Consumption | 1W |
Interface Input Inpedance | ≥5KΩ |
HART Interface Voltage Insulation Value | 50VDC |
HART Output Amplitude | 500mVpp (500Ω) |
Humidity Range | (5~95)%RH |
Working Temperature | -20℃~70℃ |
Storage Temperature | -20℃~70℃ |
Isolation Voltage | Modbus and HART interface, 500VAC |
Protection Level | IP20 |
EMC | GB/T 18268.1-2010 GB/T 18268.23-2010 |
Weight | 0.2kg |
Construction material | Housing:ABS/PA66;Clip:POM;coating:Polyester epoxy resin |
HART Master Type | The Primary or secondary master can be selected. |
HART Network Topology | Support HART point to point or multi-drop working mode, and can connect 15 instruments at most |
Burst Mode(Burst) | Support HART slave device burst mode |
HART Customized Command | Support 100 HART customized commands at most, each 5000 bytes for HART input output zone and date buffer zone. |
HART Modem Mode | Gateway can be set as HART modem mode. |
HART Sampling Resistor | Optional for internal sampling resistor or external resistor |
Modbus Baud Rate | 300,600,1200,2400,4800,9600,19200,38400,57600,115200bps, optional |
Performance:
Modbus Communication Mode | Support Modbus slave RTU and ASCII communication mode |
Modbus Function Code | 0x03/0x04/0x06/0x10 |